loading

With 25+ years of experience, we are dedicated to providing a full range of power electronics solutions

XYH  12kva  singlephase voltage optimisation 1
XYH  12kva  singlephase voltage optimisation 2
XYH  12kva  singlephase voltage optimisation 3
XYH  12kva  singlephase voltage optimisation 4
XYH  12kva  singlephase voltage optimisation 5
XYH  12kva  singlephase voltage optimisation 6
XYH  12kva  singlephase voltage optimisation 1
XYH  12kva  singlephase voltage optimisation 2
XYH  12kva  singlephase voltage optimisation 3
XYH  12kva  singlephase voltage optimisation 4
XYH  12kva  singlephase voltage optimisation 5
XYH  12kva  singlephase voltage optimisation 6

XYH 12kva singlephase voltage optimisation

The declared electricity supply in the United Kingdom and Austrilia is now, as a result of European Harmonization in 1995, 230V with a tolerance of +10% to -6%. This means that supply voltage can theoretically be anywhere between 216.2V and 253V depending on local conditions. However, the average voltage supplied from the national grid is 242V, compared to the nominal European voltage of 230V. The average supply voltage in Northern Ireland is around 239V, and 235V in the Republic of Ireland.


This statement allows you to easily operate and maintain the system. The installation, the use and the maintenance of this unit must be in strict compliance with this manual. 

Be sure to read carefully before using

In order to avoid injuries to personal safety, the unit must have solid fixings

The unit must not be installed in areas of high humidity or temperature, and not where there are flammable gases.

Opening the case of the unit invalids the warranty

5.0
design customization

    oops...!

    no product data.

    Go to homepage
    XYH  12kva  singlephase voltage optimisation (2)
    XYH 12kva singlephase voltage optimisation (2)

    Voltage Optimisation 3phsae

    Rated power 10 KVA 50KVA 100KVA
    Rated current in by-pass 20A 100A 160A
    Incoming Voltage 402V~440V 402V~440V 402V~440V
    Outgoing Voltage 365V~400V 365V~400V 365V~400V
    Frequency 50/60 HZ 50/60 HZ 50/60 HZ
    Operating Continuous Current 15A Continuous Current 76A Continuous Current 152A
    Protection 20 Amp MCB 100A Circuit breaker 160A Circuit breaker
    Operating temp. -25oC ~ 50oC -25oC ~ 50oC -25oC ~ 50oC
    Noise ≤40Db ≤40Db ≤40Db
    Protection degree IP30 IP30 IP30
    Rated power 300 KVA 500KVA 800KVA
    Rated current in by-pass 630A 800A 1250A
    Incoming Voltage 402V~440V 402V~440V 402V~440V
    Outgoing Voltage 365V~400V 365V~400V 365V~400V
    Frequency 50/60 HZ 50/60 HZ 50/60 HZ
    Operating Continuous Current 456A Continuous Current 760A Continuous Current 1215A
    Protection 630A
    Circuit breaker
    800A
    Circuit breaker
    1250A
    Circuit breaker
    Operating temp. -25oC ~ 50oC -25oC ~ 50oC -25oC ~ 50oC
    Noise ≤40Db ≤40Db ≤40Db
    Protection degree IP30 IP30 IP30
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Jinan Xinyuhua Energy Technology Co.,Ltd
    We are committed to providing global customers with a full line of power electronics solutions.
    Contact Us
    Contact person: Sky Huang
    Tel: +86-18653119810
    Phone:+86-531-58539156
    WhatsApp:+86-18653119810
    Add:

    No.220 Huayuan Road Jinan city China

    Customer service
    detect