1500kw and 3000kw
off grid inverter
Technic parameter
|
Type |
XYHWGA-1500KS |
XYHWGA-3000KS |
|
Isolation |
Low frequency transformer isolation |
|
|
Max. DC input power |
1550KWp |
3200KWp |
|
Rated input |
480Vdc |
|
|
Input voltage range |
400Vdc~600Vdc |
|
|
Nominal AC output power |
1500KW |
3000KW |
|
THD of AC current |
<3%(nominal power) |
|
|
Power factor |
>0.99(nominal power) |
|
|
Max. Efficiency |
95% |
|
|
Nominal AC output voltage |
380Vac |
|
|
Nominal AC |
50Hz± |
|
|
Automatic restart time |
2min(adjustable) |
|
|
Protection |
Input reverse connection protection,output short circuit protection, overheat protection,overload protection |
|
|
Comm. interfaces |
Ethernet |
|
|
Operating Temp. |
-20℃~+50℃ |
|
|
Relative humidity |
0~95% |
|
|
Altitude(m) |
≤6000meters(Over 2000 meters to reduce |
|
|
Cooling method |
Controlled forced-air cool |
|
|
Noise |
≤60dB |
|
|
Protection degree |
IP20(indoor) |
|
Single phase type
Technic parameter
|
Model |
XWO-13100 |
XWO -33150 |
XWO -33300 |
XWO -33450 |
XWO -33600 |
XWO -331000 |
XWO -333000 |
XWO -334500 |
XWO -336000 |
XWO -338000 |
||
|
Capacity(KVA) |
10 |
XWO |
20 |
45 |
60 |
100 |
300 |
450 |
600 |
800 |
||
|
Output currency(A) |
13.8 |
XWO |
42 |
63 |
84 |
138 |
400 |
600 |
800 |
1050 |
||
|
Circuit model |
IGBT/SPWM pulse width adjustment mode |
|||||||||||
|
AC |
Voltage |
130V-280V |
265V-495V |
|||||||||
|
Frequency |
30-70Hz |
|||||||||||
|
Phase |
single phase |
three phase four wire |
||||||||||
|
AC output voltage |
380V±1% |
|||||||||||
|
Output frequency |
50Hz/60Hz |
|||||||||||
|
frequency stability |
≤±0.01% |
|||||||||||
|
Voltage stability |
≤1% |
|||||||||||
|
Reaction time |
≤2mS |
|||||||||||
|
Wave distortion |
≤2% |
|||||||||||
|
frequency meter |
0.1Hz |
|||||||||||
|
Voltage meter |
0.1V |
|||||||||||
|
Current meter |
0. 1A |
|||||||||||
|
Power meter |
0.1W |
|||||||||||
|
Efficiency |
efficiency more than 90% ,be suit for wide-load, can be for the inductive, capacitive, resistive, and any mixed loads. |
|||||||||||
|
Protection function |
The importation of non-fuse switch, without output fuse switch, the electronic circuit to detect over-voltage Express .Over voltage, over current, over temperature, over load, short circuit, and automatic alarm. |
|||||||||||
|
Insulation reactance |
500Vdc 20MΩ |
|||||||||||
|
Pressure endurance insulation |
1500Vac/5mA/1min |
|||||||||||
|
Cooling model |
Compulsive fan cooling |
|||||||||||
|
Working temperature |
-10℃-45℃ |
|||||||||||
|
Relative humidity |
0-90%(No condensing) |
|||||||||||
|
Altitude |
1500meters |
|||||||||||
|
Dimension (W×L×H)mm |
410*440*135 |
460*440*220 |
560*350*600 |
660*400*700 |
830*450*1100 |
1160*520*1370 |
||||||
Off-grid Wind power inverter
1.Using IGBT from Mitsubishi or Infineon company as the power components
2.Using American ATEMEL company microprocessor as figure controller
3.Perfect protection and warning functions
4.Circuit frame compact,Max. Efficiency≥95%
5.With wide input voltage range
6.RS232/485 communication,multi communication interface can be selected
7.Big-screen English LCD, perfect display, interface-friendly
Technic parameter
|
Model |
XNWA220-10KS |
XNWA220- 100KS |
XNWA480- 200KS |
XNWA480- 300KS |
XNWA480- 500KS |
XNWA480- 800KS |
XNWA480- 1000KS |
||
|
DC input |
Input rating voltage(Vdc) |
480 |
|||||||
|
AC output |
Input rating current(A) |
25 |
253 |
462 |
694 |
1157 |
1851 |
2314 |
|
|
Input DC voltage allowing range(Vdc) |
420~800 |
||||||||
|
Output rating capacity(KW) |
10 |
100 |
200 |
300 |
500 |
800 |
1000 |
||
|
Output rating voltage and frequency |
AC380V/220 Vac, 50Hz(Three-phase four-wire) |
||||||||
|
Output rating current(A) |
15 |
151.5 |
303.9 |
455.8 |
759.7 |
1215.5 |
1519.4 |
||
|
Output voltage precision(V) |
AC380V±1% |
||||||||
|
Output frequency precision(Hz) |
50hz±0.05 |
||||||||
|
Wave distortion(THD) |
≤1% |
||||||||
|
Dynamic response |
3% |
||||||||
|
Power factor(PF) |
0.8leading-1-0.8lagging, adjustable |
||||||||
|
Overload ability |
150%,10 seconds |
||||||||
|
Crest factor(CF) |
3:1 |
||||||||
|
Inverted efficiency |
95% |
||||||||
|
Insulation strength |
1500 Vac,1minute |
||||||||
|
Noise (1meter) |
≤55dB |
||||||||
|
Using condition temperature |
-25℃~+55℃ |
||||||||
|
Humidity |
0-95%,non-condensing |
||||||||
|
Altitude (m) |
≤6000 |
||||||||
|
Dimension(W*D*H)mm |
800*600*980 |
800*600*2260 |
1000*800*2060 |
2000*800*2060 |
5400*600*2260 |
||||
|
Weight (Kg) |
200 |
1100 |
1500 |
1600 |
2500 |
3500 |
4500 |
||
|
Protection function |
Input reversing protection,input low-voltage protection,output over-load protection,output short-circuit protection, over-heat protection |
||||||||
No.220 Huayuan Road Jinan city China