With 25+ years of experience, we are dedicated to providing a full range of power electronics solutions

Xinyuhua 50-1000kw  DC DC Converter 1
Xinyuhua 50-1000kw  DC DC Converter 2
Xinyuhua 50-1000kw  DC DC Converter 3
Xinyuhua 50-1000kw  DC DC Converter 4
Xinyuhua 50-1000kw  DC DC Converter 5
Xinyuhua 50-1000kw  DC DC Converter 6
Xinyuhua 50-1000kw  DC DC Converter 1
Xinyuhua 50-1000kw  DC DC Converter 2
Xinyuhua 50-1000kw  DC DC Converter 3
Xinyuhua 50-1000kw  DC DC Converter 4
Xinyuhua 50-1000kw  DC DC Converter 5
Xinyuhua 50-1000kw  DC DC Converter 6

Xinyuhua 50-1000kw DC DC Converter

Working principle
Bidirectional DCDC converter is applied to new energy, which operates in cooperation with battery, battery, DC bus, motor controller and motor to realize various operation conditions of new energy, energy recovery and prolong the service life of battery.

Function introduction

Realize the two-way flow of energy, that is, it can charge from the battery side to the bus and charge the battery from the bus side
It has full-automatic protection functions such as overheating, overvoltage, overload and overcurrent

Original imported power devices shall be selected
The main control chip adopts microchip industrial MCU and full digital circuit design
 All industrial chips are used, which can operate normally in cold, high temperature and humid environment.
Standard RS-232 communication, RS-485, GPRS, Ethernet and other communication modes can be selected to meet the needs of different occasions to the greatest extent

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Technic Parameter

    Model 50K-1000kw DC-DC
    Operation mode Continuous work
    Rated output power (KW) 50-1000kw
    High voltage side parameters
    Max.power( KW) 50-1000kw
    DC voltage range DC 50V-850V
    Current range 0--±160A(3200A)
    Voltage stabilizing accuracy <0.1%F.S.
    Current stabilizing accuracy <0.1%F.S.
    DC voltage ripple <0.3%F.S.
    Low voltage side parameters
    Max.power( KW) 50-1000kw
    DC voltage range DC  0-800V 
    Current range 0--±200A(4000A)
    Voltage stabilizing accuracy <0.1%F.S.
    Current stabilizing accuracy <0.1%F.S.
    DC voltage ripple <0.3%F.S.
    System
    System power supply 1. AC 220 V (required when the low voltage side voltage is lower than 180V) 2. The low voltage side voltage is between 180v-750v
    Noise 65dB
    Protect Class IP21
    Allowable ambient temperature -20℃~+45℃
    Cooling mode Forced air cooling
    Allowable relative humidity 0~95% ( non-condensing )
    Max. allowable altitude ≤2000m(derating over 2000m )
    Emergency stop Yes (via emergency stop button)
    Display and communication
    Display External touch screen
    Standard communication mode Ethernet / RS232 (Modbus Protocol)

    Interface introduction

    The equipment interface has three interfaces: RS232 \ RS485 \ Ethernet

    RS232 is responsible for real-time communication with the lower computer control board for data acquisition,Communication protocol internal customization.

    RS485 interface is connected with remote equipment for remote control, and the equipment address can be set; Communication setting: 9600, N, 8,1; The communication protocol is standard Modbus protocol;

    Ethernet interface is connected with remote equipment for remote control, and IP can be set; The communication protocol is standard modbustcpip protocol; The device address can be set3 

    Touch screen bit MODBUS server mode

    to be filled in correctly

    Local IP address 192.168.1.102

    Local port number 3000

    Remote IP address 192.168.1.100

    Remote port number 3000

    B-2 (2)

    Modbus TCPIP and Modbus RS485

    Equipment interface

    The following is a detailed explanation of the agreement

    DC:DC Error Code Description

    No. Variable name R Read / write type Register details Register address (offset -1) Variable units and decimal places
    1   R 16 bit unsigned binary 1  
    2   R 16 bit unsigned binary 2  
    3 Ua R 16 bit unsigned binary 3 1V
    4   R 16 bit unsigned binary 4 1A
    5 Ub R 16 bit unsigned binary 5 1V
    6   R 16 bit unsigned binary 6 1A
    7 Uc R 16 bit unsigned binary 7 1V
    8   R 16 bit unsigned binary 8 1A
    9   R 16 bit unsigned binary 9 1V
    10   R 16 bit unsigned binary 10 1V
    11   R 16 bit unsigned binary 11 1V
    12 Freq2 R 16 bit unsigned binary 12 0.1HZ
    13 Udc bus R 16 bit unsigned binary 13 1V
    14 Udc_2 R 16 bit unsigned binary 14 1V   bias-32767
    15 Idc_1 R 16 bit unsigned binary 15 1A   bias-32767
    16 Udc_3 R 16 bit unsigned binary 16 1V   bias-32767
    17   R 16 bit unsigned binary 17  
    18   R 16 bit unsigned binary 18  
    19   R 16 bit unsigned binary 19 0.1KW
    20   R 16 bit unsigned binary 20  
    21   R 16 bit unsigned binary 21 0=OFF 1=ON
    22   R 16 bit unsigned binary 22 3=Normal   2=DC power source
    23   R 16 bit unsigned binary 23 Total charge 1*65535+ total charge 2 0.1kwh
    24   R 16 bit unsigned binary 24  
    25   R 16 bit unsigned binary 25 Total discharge 1*65535+ total discharge 2 0.1kwh
    26   R 16 bit unsigned binary 26  
    27 ErrorFlag dc R 16 bit unsigned binary 27  
    28 StartFlag dc R 16 bit unsigned binary 28 0=OFF 1=ON
    29 Mode Flag dc R 16 bit unsigned binary 29  
    30   R 16 bit unsigned binary 30 2= constant voltage, constant current and constant power at low voltage side 6= constant voltage at high voltage side
    31   RW 16 bit unsigned binary 31  
    32   RW 16 bit unsigned binary 32 1V
    33   RW 16 bit unsigned binary 33 1KW
    34   RW 16 bit unsigned binary 34 1KVAR
    35   RW 16 bit unsigned binary 35 3=Normal   2=DC power source
    36   RW 16 bit unsigned binary 36  
    37   RW 16 bit unsigned binary 37  
    38   RW 16 bit unsigned binary 38  
    39   RW 16 bit unsigned binary 39  
    40   RW 16 bit unsigned binary 40  
    41 Start Stop dc RW 16 bit unsigned binary 41  
    42   RW 16 bit unsigned binary 42 1V
    43 Udcset RW 16 bit unsigned binary 43 1V    bias-32767
    44 Idcset RW 16 bit unsigned binary 44 1A
    45 Pdcset RW 16 bit unsigned binary 45 1KW
    46 ModeFlagSetdc RW 16 bit unsigned binary 46 2= constant voltage, constant current and constant power at low voltage side 6= constant voltage at high voltage side

    Error code description

    1=DC overvoltage Output overvoltage
    2= DC short voltage Input short voltage
    10=over current  
    14=over heat  
    17= IGBT overcurrent  
    19=system  
    20=stop  
    21= linkage  
    Get in touch with us
    just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
    Related Products
    no data
    Jinan Xinyuhua Energy Technology Co.,Ltd
    We are committed to providing global customers with a full line of power electronics solutions.
    Contact Us
    Contact person: Sky Huang
    Tel: +86-18653119810
    Phone:+86-531-58539156
    WhatsApp:+86-18653119810
    Add:

    No.220 Huayuan Road Jinan city China

    Customer service
    detect