Performance characteristics
● Adopt advanced IGBT/SPWM technology,small capacity,low noise,high reliability
● A lot of input immunity scope design,input the adapter power generator
● Double isolation from the input and output,safe and reliability
● Output pure sine wave, the wave shape is pure and steady
● Perfect protection function
Executive standard
● GJB 181b-2012 aircraft power supply characteristics
● GJB 572a-2006 aircraft external power supply characteristics and general requirements
● MH / T 6018-2014 aircraft ground static power supply
● GJB 5189-2003 aircraft power supply characteristic parameter test method
● GJB 1440-92 definition and basic requirements of electrical and electronic equipment enclosure
● GJB 151b-2013 requirements for electromagnetic emission and sensitivity of military equipment and subsystems
● GJB 150.8a-2009 environmental test method for military equipment Part 8: rain test
● GJB 150.9a-2009 environmental test methods for military equipment Part 9: hygrothermal test
●GB 5226.1-2009 electrical safety of machinery electrical equipment of machinery part 1: General technical conditions
● GB 4793.1-2007 safety requirements for electrical equipment for measurement, control and laboratory use Part 1: General requirements
GPU 400HZ frequency converter parameter
| Model | 13030 | 13060 | 13100 | 33200 | 33450 | 33600 | 33900 | 331500 | 333000 |
| Capacity | 3KVA | 6KVA | 10KVA | 20KVA | 45KVA | 60 KVA | 90KVA | 150KVA | 300KVA |
| Circuit mode | IGBT/SPWM | ||||||||
| Output frequency | 400Hz/300~500Hz | ||||||||
| Load stability | ≤±1% | ||||||||
| Frequency stability | ≤±0.01% | ||||||||
| Input | 220V±20% | 400V±20% (45~65hz) | |||||||
| Input phase | 1phase | 3phase 4wires | |||||||
| three phases imbalance. | phase120°±2° ;phase difference<3% rated value | ||||||||
| Wave distortion | THD≤2% | ||||||||
| Outputvoltage | 3phase 4wires ;115V(200V)±20% or 21V(36V)±20% | ||||||||
| Over load ability | 125% for 30 min; 150% for 90 sec;200% for 20 sec. | ||||||||
| Protection function | ≤2mS | ||||||||
| Meter Display | Frequency、voltage、current、power、power factor 4 number display | ||||||||
| Protection function | Over voltage, over current, over temperature, over load, short circuit, and automatic alarm. | ||||||||
| Insulation reactance | 500Vdc 20MΩ | ||||||||
| Pressure endurance insulation | 1800Vac/5mA/1 minute | ||||||||
| Cooling mode | Compulsive fan cooling | ||||||||
| Protect grade | IP20/IP32(optional) | ||||||||
| Mobile function | With Trailor or without Trailor(optional) | ||||||||
| Working temperature | -20℃~50℃ | ||||||||
| Relative humidity | 0-90%(No condensation) | ||||||||
| Altitude | 1500 meters | ||||||||
| Dimension(W×L×H)mm | 660×400×800 | 830×450×1100 | 520×1160×1370 | 600×1320×1440 | 1850×1100×1750 | ||||
Product scenario